Servicios
Descargas
Buscar
Idiomas
P. Completa
Evaluation of chloride migration in ultra-high performance concrete (UHPC) with glass powder
L. V. Dias; S. M. Soares; J. A. Salvador Filho;
L. V. Dias; S. M. Soares; J. A. Salvador Filho; F. G. S. Ferreira
Evaluation of chloride migration in ultra-high performance concrete (UHPC) with glass powder
Avaliação da migração de cloretos em compósitos cimentícios de ultra alto desempenho com pó de vidro
Evaluación de la migración de cloruro en compuestos cementosos de ultra alto rendimiento con polvo de vidrio
Revista de la Asociación Latinoamericana de Control de Calidad, Patología y Recuperación de la Construcción, vol. 11, núm. 2, 61 – 75, 2021
Asociación Latinoamericana de Control de Calidad, Patología y Recuperación de la Construcción, A. C.
resúmenes
secciones
referencias
imágenes

Abstract: The influence of glass powder incorporation to ordinary concrete regarding mechanical and durability properties has been studied. This work aims to evaluate the durability of ultra-high performance cementitious composites (UHPCC) with partial substitution of Portland cement by glass powder, through chloride migration test according to the NT Build 492 methodology. With this aim, specimens with 0%, 10%, 20%, 30% and 50% content of glass powder by weight of Portland cement were cast, cured in lime saturated water until the age of 28 days. The results indicate that minor contents of glass powder do not harm the concrete properties and higher contents maintain good mechanical and durability characteristics.

Keywords:cementitious compositecementitious composite,glass powderglass powder,chloride migrationchloride migration.

Resumo: O pó de vidro incorporado ao concreto convencional vem sendo estudado em relação à sua influência na resistência mecânica e durabilidade. Este trabalho visa avaliar a durabilidade de compósitos cimentícios de ultra alto desempenho (CCUAD) com substituição parcial do cimento por vidro finamente moído, por meio do ensaio de migração de cloretos utilizando o método da NT Build 492. Para tanto foram moldados corpos de prova com teores de pó de vidro de 0%, 10%, 20%, 30% e 50% em relação ao volume de cimento e a avaliação foi feita na idade de 28 dias. Os resultados indicam que, em teores baixos, o pó de vidro não prejudica as propriedades dos compósitos e em teores mais altos os compósitos mantêm boas características mecânicas e de durabilidade.

Palavras-chave: compósito cimentício, pó de vidro, migração de cloretos.

Resumen: Se ha estudiado la incorporación de polvo de vidrio en el hormigón convencional por su influencia en la resistencia mecánica y la durabilidad. Este trabajo tiene como objetivo validar la durabilidad de los compuestos cementosos de ultra alto desempeño (CCUAD) con reemplazo parcial de cemento por vidrio finamente molido, a través del ensayo de migración de cloruros, utilizando el método NT Build 492. Para ello, fueron moldeadas probetas conteniendo valores de 0%, 10%, 20%, 30 % y 50% de polvo de vidrio en relación al volumen de cemento, y la evaluación se realizó a los 28 días de edad. Los resultados indican que, con valores bajos, el polvo de vidrio no perjudica las propiedades de los compuestos y, a niveles superiores, los compuestos mantienen características mecánicas y durabilidad adecuadas.

Palabras clave: compuesto cementoso, polvo de vidrio, migración de cloruro.

Carátula del artículo

Investigación básica

Evaluation of chloride migration in ultra-high performance concrete (UHPC) with glass powder

Avaliação da migração de cloretos em compósitos cimentícios de ultra alto desempenho com pó de vidro

Evaluación de la migración de cloruro en compuestos cementosos de ultra alto rendimiento con polvo de vidrio

L. V. Dias
Universidade Federal de São Carlos, Brasil
S. M. Soares
Instituto Federal de Educação, Ciência e Tecnologia de São Paulo, Brasil
J. A. Salvador Filho
Instituto Federal de Educação, Ciência e Tecnologia de São Paulo, Brasil
F. G. S. Ferreira
Universidade Federal de São Carlos, Brasil
Revista de la Asociación Latinoamericana de Control de Calidad, Patología y Recuperación de la Construcción, vol. 11, núm. 2, 61 – 75, 2021
Asociación Latinoamericana de Control de Calidad, Patología y Recuperación de la Construcción, A. C.

Recepción: 12 Septiembre 2020

Aprobación: 11 Marzo 2021

Publicación: 01 Mayo 2021

1. INTRODUCTION

Thus, the main objective of this work is to evaluate the durability of ultra-high-performance cementitious composites (UHPCC) with partial substitutions of Portland cement by glass powder, at the contents of 10%, 20%, 30% and 50%, focusing on chloride penetration, through chloride migration assay.

The term ultra-high-performance concrete was first used by de Larrard and Sedran (1994). It is usually related to a high compressive strength composite (reaching 4 times the strength of ordinary concrete), according to Bahedh and Jafar (2018). Morover, its development applies particle packaging models that leads to a high durability material (Alkaysi et al., 2015).

Silica fume is usually employed in the production of ultra-high performance cementitius composite, in addition to a high Portland cement consumption (about 800 – 1000 kg/m³) (Bahedh and Jafar, 2018; Ganesh and Murthy, 2018), and smaller aggregates when compared to ordinary concrete. However, due to the high environmental impact generated in Portland cement production, since about 0.8 tons of CO2 are released to produce one ton of Portland cement (Mehta and Ashish, 2020), ultra-high performance cementitious matrices meet current trends in carbon footprint reduction, with the use of high levels of supplementary cementitious materials in partial replacement of Portland cement. Supplementary cementitious materials have been widely used to as partial replacement of Portland cement in concrete either as filler or pozzolanic material.

Adaway and Wang (2015) used residual glass as a partial substitute for the fine aggregate in structural concrete and found that concrete containing up to 30% of fine glass aggregate exhibits greater compressive strength than ordinary concrete.

Du and Tan (2017) studied the incorporation of high volume of glass powder as a partial substitute of Portland cement in cementitious composites and obtained better mechanical behaviors and higher performance in terms of durability.

Studies conducted by Afshinnia and Rangaraju (2015) showed satisfactory results in mitigating the alkali-silica reaction when glass powder was used as a pozzolanic material in partial replacement to cement.

High and ultra-high-performance concretes should solve the durability problem on chloride attack in ordinary structural concrete due to their dense microstructure (Sohail et al., 2021).

The European Union generated about 25.8 Mt of glass waste in 2007 (Abdollahnejad et al., 2017). Brazil consumed 5.5 kg/inhabitants. of which 80% were not recycled in 2008, according to data from the Institute for Applied Economic Research (IPEA, 2012). Thus, glass residue is an abundant material whose use can help to reduce the environmental impact, both as supplementary cementitious material in concrete production, as well as in Portland cement manufacture as a pozzolanic material. Glass powder can be used as partial replacement of Portland cement aiming to reduce carbon emissions from the Civil Construction industry considering its high silica (SiO2) content, its amorphous structure and pozzolanic characteristics, (Mehta and Ashish, 2020).

Thus, the main objective of this work is to evaluate the durability of ultra-high-performance cementitious composites (UHPCC) with partial substitutions of Portland cement by glass powder, at the contents of 10%, 20%, 30% and 50%, focusing on chloride penetration, through chloride migration assay.

2. MATERIALS AND METODOS
2.1 Materials

Portland cement type CPV-ARI, silica fume and glass powder were used as binders. Glass powder with particles size smaller than 75 μm was used. Glasses classified as soda-lime were processed from post-consumption amber bottles to minimize uncontrolled variations due to pigments. After collecting, the glass bottles were washed in water with detergent to remove labels, caps, glue, and impurities. It was air dried and crushed in a concrete mixer loaded with chrome-steel spheres. After grinding, the crushed glass was grounded in a ball mill, with balls of the same material. The glass resulting from grinding in ball mill was dried in an oven at 110°C ± 5°C for 24 hours. After dried, the glass was sifted in a mechanical sieve shaker in batches of 200g for 15 minutes. Figure 1 presents the glass powder processing.


Figure 1
Recycled glass powder processing.
Source: Adapted from Freitas (2019).

Ground materials were packed in paper and plastic bags, avoiding contact with moisture. In addition, a natural fine quartz aggregate with a maximum dimension of 1.2 mm was used. Superplasticizer admixtures based on polycarboxylate were also used to ensure low water/binder ratio and shrinkage reducing admixture to avoid matrix cracking. The physical characteristics of Portland cement, silica fume, glass powder and sand are presented in Tables 1, 2 and 3, respectively. The number of tests were fulfilled according to each specific Brazilian standard.

Table1
Portland Cement physical characteristics.

Table 2
Silica fume and glass powder physical characteristics.

* tested according NBR 5751 (ABNT, 2015) method.** Reference values from NBR 12653 (ABNT, 2015).

Table 3
Fine aggregate physical characteristics.

In Table 4 the chemical characteristics of Portland cement, silica fume, glass powder and fine aggregate are presented.

Table 4
Materials chemical composition.

* Reference values from NBR 16697 (ABNT, 2018).** Reference values from NBR 13956-1 (ABNT, 2012).

In Figure 2 the granulometric distribution of Portland cement, silica fume, glass powder and fine aggregate (quartz sand) from three samples each test are presented. In these results it is possible to observe D50 parameter of 0.8 μm for silica fume, 7 μm for Portland cement, 15 μm for glass powder and 270 μm for quartz sand.


Figure 2
Figure 2.

2.2 Methodology

For ultra-high performance cementitious composites production, a water/binder ratio of 0.18 was adopted for all mixtures, the silica fume content was 0,8% of the Portland cement weight of the reference mixture. Glass powder was added in contents of 0%, 10%, 20%, 30% and 50% in volumetric replacement of Portland cement, and the mixtures were named REF, VD10, VD20, VD30 and VD50, respectively. In addition, an amount of 2.25% of superplasticizer admixture was used to obtain a consistency index of 380±10mm (fluid consistency), and shrinkage reductor admixture in content of 1%, as recommended by the manufacturer. The binder-admixture compatibility was evaluated by the mini slump test, according to the Kantro test (1980).

The consistency of cementitious composites (Figure 3) was verified according to NBR 13276 (ABNT, 2016) and the mass density and incorporated air content of the composites in the fresh state were determined according to NBR 13278 (ABNT, 2005).


Figure 3
Slump flow test for consistency determination.

In Table 5 it is shown the unitary proportions, Portland cement consumption and consistency for each mixture. The nomenclature SP refers to the superplasticizer admixture and RR, to the shrinkage reducing admixture.

Table 5
Mixture ratios and consistency index for each composite.

The materials consumption of each cementitious composites mixture evaluated are presented in Table 6.

Table 6.
Cementitious composites material consumption in kg/m³.

* Water consumption adjusted considering the solids content present in superplasticizer.

For the hardened state properties assay, 5x10 cm cylindrical specimens were manually dense molded and cured in lime saturated water. The axial compressive strength test for UHPCC was performed according to NBR 5739 (ABNT, 2018) at the age of 28 days on four specimens per mixture. The test to obtain the static modulus of elasticity of UHPCC was performed according to NBR 8522 (ABNT, 2017) at the age of 28 days on three specimens per mixture.

For durability assay, water absorption by capillarity of CCUAD at the age of 28 days was performed, following the recommendations of NBR 9779 (ABNT, 2012) in three 5x10 cm cylinder specimens per mixture, and chloride migration coefficient in the non-stationary state (according to NT Build 492) on two 10x20 cm cylinder specimens for each mixture.

The chloride diffusion test device is shown in Figure 4.


Figure 4.
Chloride diffusion test apparatus.

The specimens were cut into four equal parts of 10 x 5 cm, using the two inner samples for the test. After being cut, the samples underwent the preconditioning process in a vacuum container with both faces exposed to an internal pressure between 1 and 5 KPa. Subsequently, the container was filled with a Ca(OH)2 solution until the samples were fully immersed. The vacuum was kept in the container to ensure the saturation of the cementitious composite pores with the solution. Two solutions were then prepared, the reaction solution of water with sodium chloride (NaCl) at 10%, and the anode solution of water with sodium hydroxide (NaOH) at 0.3 M. After being removed from the vacuum, the samples were placed in tubes, and the interfaces sealed with silicone to ensure that only the faces were in contact with the solutions. A container was filled with NaCl solution and the NaOH solution was placed in the tubes above the samples. The tubes with the samples were then placed in the container containing the NaCl solution. The positive pole of the energy source was connected to the anode and the negative to the frame, and the current was passed through the system to accelerate the Cl- ions migration through the samples. The test time and voltage are defined based on the initial current passing through the system, according to the recommendations of NT Build 492. The samples were then removed from the apparatus, splitted by diametral compression, and a 0.1M silver nitrate (AgNO3) solution was sprayed to highlight the chloride penetration depth in the samples. This depth was then measured with a caliper and the chloride migration coefficient was determined in the non-stationary state by Equation 1, where Dnssm represents the migration coefficient in the non-stationary state (10-12 m²/s), U the applied voltage (V), T the average of the initial and final temperature of the anode (°C), L the sample height (mm), xd the penetrations depth average (mm), and t the test duration (hours).

D n s s m = 0.0239 (273 + T) L U - 2 t χ d 0.0238 (273 + T) L X d U - 2 (1)

The results were analyzed in terms of analysis of variance (ANOVA), and in cases where F > Fcritical, the Tukey test was applied.

3. RESULTS AND DISCUSSION

The results of mass density, incorporated air content, compressive strength, static elasticity modulation and water absorption by capillarity of ultra high performance cementitious composites at the age of 28 days are shown in Table 7. In the Table 7 the letter A indicates that the value is statistically equal to the reference, while the letter B indicates statistical difference compared to the reference mixture.

Table 7
Mechanical and physical characteristics of the UHPCC studied.

An increase of around 1% in mass density was observed for the VD10, VD20 and VD30 samples when compared to the REF samples, while the composite density with 50% replacement of Portland cement by glass powder decreased by 1.47%. The incorporated air content results presented a reduction with the increase of glass powder content. Regarding compressive strength, static modulus of elasticity and water absorption, there is a variation between the values, however no sample presents a statistically significant difference when compared to the reference sample, except for VD50 compressive strength which decreased by 23.5% in comparison to REF.

Li et al. (2019) and Lee et al. (2018) added glass powder to the Portland cement paste in contents from 0% to 25% with a/c ratio 0.41, and observed the compressive strength decrease with increasing of glass powder amount. The decrease in the compressive strength of the Portland cement paste with glass powder can be explained by the dilution effect. The dilution effect of glass powder reduces the Portland cement content and increases the effective water/cement ratio, to reduce the formation of hydration products and, finally, reduces the compressive strength of the Portland cement paste (Du et al., 2020). This is also observed in other studies. According to Du and Tan (2017), the pozzolanic reaction of glass powder is relatively slower and therefore the resistance in the early ages of concrete is reduced when compared to Portland cement hydration. However, with a longer curing age, the benefits of the glass powder's pozzolanic reaction begin to appear.

Sohail et al. (2018) have charted several studies relating compressive strength results and the respective water/binder ratio. The results of the 28-day compressive strength tests of reference cementitious composites and Portland cement replacement by glass powder found in the present study were included into the same chart (Figure 5).


Figure 5
Effect of water-to-binder ratio on compressive strength of HPC and UHPC
Adapted from Sohail et al. (2018).

By reducing the water/binder ratio the compressive strength increases; however, for CCUAD mixtures in the same water/binder ratio, different compressive strengths were achieved due to other factors, such as the amount and type of Portland cement or silica fume.

The results of the chloride penetration depth and the chloride diffusion coefficients in the non-stationary state are presented in Table 8.

Table 8
Chloride penetration depth and chloride diffusion coefficient on 28-day age samples.

The results of chloride diffusion coefficient at 10 -12m²/s, as well as the average depth of chloride penetration are shown in Figure 6. It is emphasized that the sample results pointed with the letter A are statistically equal to the reference samples, while those pointed with the letter B are statistically different when compared to the reference results.


Figure 6
Chloride diffusion coefficient and penetration depth.

It is observed that there was an increase in the migration coefficient of cementitious composites with the increase of glass powder content (except for the vd20 mixture). This fact can be explained due the glass powder particles (D50=15μm) are larger than Portland cement particles (D50=7μm), leading to a different particle packaging (filer effect of glass powder), in addition to the pozzolanic reactions of glass powder being slower than the Portland cement hydration reactions, that can develop up to older ages as observed by Du and Tan (2015). Thus, samples with higher glass content trend to present a lower C-S-H content at intermediate ages when compared to those with lower content or without glass powder. Tam et al. (2012) found that a higher C-S-H content leads to a lower volume of pores and their disconnection, so samples with lower C-S-H content tend to have a higher chloride penetration depth.

Also, the fact that water absorption content tends to increase as the percentage of glass powder increases, as shown in Table 7, is another indication of porosity growth with the increase in glass powder content.

The depth of chloride penetration at 28 days results follows the chloride diffusion coefficient for all mixtures, except for the mixture with 20% of glass powder replacement.

For the chloride diffusion coefficient, the statistical analysis shows that the replacement of Portland cement by 50% of glass powder induced a significant effect when compared to all mixtures evaluated.

However, it is worth mentioning that all obtained results for chloride penetration depth and chloride migration were lower than those observed in other studies with ultra-high performance materials. Chen et al. (2018) and Mosavinejad et al. (2020) evaluated the diffusion coefficient of chlorides in UHPCC obtaining chloride penetration depths around 5 mm and diffusion coefficients of 2*10-12m²/s. In addition, when comparing the values obtained in this work with those in Table 9, it is verified that all mixtures are classified with extreme high resistance to chloride penetration.

Tabela 9
Resistance to chloride penetration of various types of concrete based on the 28-day chloride diffusivity.

Adapted from Teng et al. (2018).

Castellote, Andrade and Alonso (2001) and Santos (2006) analyzed the chloride diffusion tests in ordinary concretes with and without silica fume incorporation, varying the water/cement ratio, and justified the reduction of diffusion coefficients due to a reduction in the water/binder ratio followed by a reduction in total porosity due to the decrease in this relationship. In the present work, the water/binder ratio was constant, which provided a significant increase in the water/cement ratio of the VD50, which may have caused its porosity increase.

According to Li et al. (2020), the chloride ions diffusion coefficients of UHPCC varied from 0.02 x 10-12 m2/s to 0.41 x 10-12 m2/s depending on the water/cement ratio, curing procedure, fiber volume and age of the tests. Due to the large number of parameters involved in performed tests available in the literature, it is difficult to compare quantitatively the chloride ions diffusion in CCUAD.

4. CONCLUSIONS

In accordance with the results obtained, it is concluded that:

  1. 1. Whereas all mixtures studied achieved high compressive strength and high modulus of elasticity, low water absorption and high resistance to penetration and diffusion of chlorides, all are ultra-high performance cementitious composites, with or without the incorporation of glass powder.
  2. 2. Partial replacement of large Portland cement contents by glass powder (50%) may cause changes on the properties of the cementitious composites at the age of 28 days.
  3. 3. The coefficients obtained are still much lower than those in the literature, indicating high mechanical resistance and extremely high resistance to chloride penetration. Thus, glass powder is a viable substitute for Portland cement in terms of chloride penetration durability.
  4. 4. Considering the significant reduction of Portland cement amount in cementitious composite with the replacement of 50% of cement by glass powder, and depending on the characteristics presented by the material, its use is recommended when compared to the other composites studied. This is the most economical alternative and provides lower environmental impacts.

Material suplementario
Información adicional

Cite as: Dias, L. V., Soares, S. M., Salvador Filho, J. A., Ferreira, F. G. S. (2021), "Evaluation of chloride migration in ultra-high performance concrete (UHPC) with glass powder", Revista ALCONPAT, 11 (2), pp. 61 – 75, DOI: https://doi.org/10.21041/ra.v11i2.512

Contribution of each author: In this work, the author L. V. Dias contributed with the activities of conceptualization, development, results and discussion, writing and preparation of the original text (30%); S. M. Soares contributed to the activities of conceptualization, development, results and discussion (30%); J. A. Salvador Filho contributed with conceptualization, supervision, discussion of results, writing and review (20%) and F. G. S. Ferreira contributed with conceptualization, supervision, discussion of results, writing and review (20%).

Creative Commons License: Copyright 2021 by the authors. This work is an Open-Access article published under the terms and conditions of an International Creative Commons Attribution 4.0 International License (CC BY 4.0).

Discussions and subsequent corrections to the publication: Any dispute, including the replies of the authors, will be published in the second issue of 2022 provided that the information is received before the closing of the first issue of 2022.

Legal Information: Revista ALCONPAT is a quarterly publication by the Asociación Latinoamericana de Control de Calidad, Patología y Recuperación de la Construcción, Internacional, A.C., Km. 6 antigua carretera a Progreso, Mérida, Yucatán, 97310, Tel.5219997385893, alconpat.int@gmail.com, Website: www.alconpat.org Reservation of journal title rights to exclusive use No.04-2013-011717330300-203, and ISSN 2007-6835, both granted by the Instituto Nacional de Derecho de Autor. Responsible editor: Pedro Castro Borges, Ph.D. Responsible for the last update of this issue, Informatics Unit ALCONPAT, Elizabeth Sabido Maldonado. The views of the authors do not necessarily reflect the position of the editor. The total or partial reproduction of the contents and images of the publication is carried out in accordance with the COPE code and the CC BY 4.0 license of the Revista ALCONPAT.

Acknowledgments

5. ACKNOWLEDGMENT

To the National Council for Scientific and Technological Development (CNPq) for financial assistance to carry out this research, and to the Institute of Technological Research of the State of São Paulo (IPT) for its support on the binders´characterization tests.

6. REFERENCES
Abdollahnejad, Z., Kheradmand, M., Pacheco-Torgal, F. (2017), Short-Term Compressive Strength of Fly Ash and Waste Glass Alkali-Activated Cement-Based Binder Mortars with Two Biopolymers. Journal of Materials in Civil Engineering. 29(7). https://doi.org/10.1061/(ASCE)MT.1943-5533.0001920
Adaway, M., Wang, Y. (2015), Recycled glass as a partial replacement for fine aggregate in structural concrete – Effects on compressive strength. Electronic Journal of Structural Engineering. 14(1):116-122.
Afshinnia, K., Rangaraju, P. R. (2015), Influence of fineness of ground recycled glass on mitigation of alkali-silica reaction in mortars. Construction and Building Materials. 81: 257-267. https://doi.org/10.1016/j.conbuildmat.2015.02.041
Alkaysi, M., El-Tawil, S., Liu, Z., Hansen, W. (2016), Effects of silica powder and cement type on durability of ultra high performance concrete (UHPC). Cement and Concrete Composites. 66: 47- 56. https://doi.org/10.1016/j.cemconcomp.2015.11.005
Associação Brasileira de Normas Técnicas. (2000). NM 30: Agregado miúdo – Determinação da absorção de água. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2006). NM 45: Agregados - Determinação da massa unitária e do volume de vazios. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2003). NM 46: Agregados - Determinação do material fino que passa através da peneira 75 μm, por lavagem. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2001). NM 49: Agregado miúdo - Determinação de impurezas orgânicas. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2009). NM 52: Agregado miúdo - Determinação da massa específica e da massa específica aparente. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2003). NBR 248: Agregados - Determinação da composição granulométrica. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2018). NBR 5739: Concreto – Ensaio de compressão de corpos de prova cilíndricos. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2015). NBR 5751 Materiais pozolânicos – Determinação da atividade pozolânica com cal aos sete dias. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2019). NBR 7215: Cimento Portland - Determinação da resistência à compressão de corpos de prova cilíndricos. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2013). NBR 7681-2: Calda de cimento para injeção. Parte 2: Determinação do índice de fluidez e da vida útil – Método de ensaio. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2017). NBR 8522: Concreto – Determinação dos módulos estáticos de elasticidade e de deformação a compressão. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2012). NBR 9779: Argamassa e concretos endurecidos - Determinação da absorção de água por capilaridade. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2013). NBR 11579: Cimento Portland - Determinação do índice de finura por meio da peneira 75 μm (nº200). Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2015). NBR 12653: Materiais pozolânicos — Requisitos . Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2016). NBR 13276: Argamassa para assentamento e revestimento de paredes e tetos – Determinação do índice de consistência. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2005). NBR 13278: Argamassa para assentamento e revestimento de paredes e tetos - Determinação da densidade de massa e do teor de ar incorporado. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2012). NBR 13956-1: Sílica ativa para uso com cimento Portland em concreto, argamassa e pasta. Parte 1: Requisitos. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2010). NBR 15895: Materiais pozolânicos – Determinação do teor de hidróxido de cálcio fixado – Método Chapelle modificado. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2015). NBR 16372: Cimento Portland e outros materiais em pó - Determinação da finura pelo método de permeabilidade ao ar (método de Blaine). Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2017). NBR 16605: Cimento Portland e outros materiais em pó - Determinação da massa específica. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2018). NBR 16606: Cimento Portland - Determinação da pasta de consistência normal. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2018). NBR 16607: Cimento Portland - Determinação dos tempos de pega. Rio de Janeiro.
Associação Brasileira de Normas Técnicas. (2018). NBR 16697: Cimento Portland - Requisitos. Rio de Janeiro.
Bahedh, M. A., Jaafar, M. S. (2018), Ultra High-Performance Concrete Utilizing Fly Ash as Cement Replacement under Autoclaving Technique. Case Studies in Construction Materials. 9. https://doi.org/10.1016/j.cscm.2018.e00202
Castellote, M., Andrade, C., Alonso, C. (2001), Measurement of the steady and non-steady-state chloride diffusion coefficients in a migration test by means of monitoring the conductivity in the anolyte chamber. Comparison with natural diffusion tests. Cement and Concrete Research. 31(10): 1411-1420 https://doi.org/10.1016/S0008-8846(01)00562-2
Chen, Y., Yu, R., Wang, X., Chen, J., Shui, Z. (2018), Evaluation and optimization of Ultra-High Performance Concrete (UHPC) subjected to harsh ocean environment: Towards an application of Layered Double Hydroxides (LDHs). Construction and Building Materials. 177: 51-62. https://doi.org/10.1016/j.conbuildmat.2018.03.210
de Larrard, F., Sedran, T. (1994), Optimization of ultra-high perfomance concrete by the use of a packing model. Cement and Concrete Research. 24(6):997-1009. https://doi.org/10.1016/0008-8846(94)90022-1
Du, H., Tan, K. H. (2014). Effect of particle size on alkali-silica reaction in recycled glass mortars. Construction and Building Materials. 66: 275-285. https://doi.org/10.1016/j.conbuildmat.2014.05.092
Du, H., Tan, K. H. (2017), Properties of high volume glass powder concrete. Cement and Concrete Composites.75: 22-29.
Du, Y., Yang, W., Ge, Y., Wang, S., Liu, O. (2020), Thermal conductivity of cement paste containing waste glass powder, metakaolin and limestone filler as supplementary cementitious material. Journal of Cleaner Production. 287. https://doi.org/10.1016/j.jclepro.2020.125018
Freitas, T. O. (2019), “Efeito do pó de vidro na mitigação da reação álcali-sílica de compósitos cimentícios de alto desempenho”, Dissertação de Mestrado, Universidade Federal de São Carlos, p.148.
Instituto de pesquisa econômica aplicada (IPEA) (2012), Diagnóstico dos Resíduos Sólidos Urbanos. Disponível em: https://www.ipea.gov.br/portal/images/stories/PDFs/relatoriopesquisa/121009_relatorio_residuos_solidos_urbanos.pdf. Acesso em: 27 de março de 2020.
Kantro, D. (1980), Influence of Water-Reducing Admixtures on Properties of Cement Paste—A Miniature Slump Test. Cement, Concrete and Aggregates. 2(0):95-102. https://doi.org/10.1520/CCA10190J
Lee, H., Hanif, A., Usman, M., Sim., J., Oh, H. (2018), Performance evaluation of concrete incorporating glass powder and glass sludge wastes as supplementary cementing material. Journal of Cleaner Production. 170: 683-693. https://doi.org/10.1016/j.jclepro.2017.09.133
Li, J., Wu, Z., Shi, C., Yuan, Q., Zhang, Z. (2020), Durability of ultra-high performance concrete: a review. Construction and Building Materials. 255. https://doi.org/10.1016/j.conbuildmat.2020.119296
Li, P. P., Yu, Q.L., Brouwers, H.J.H., Chen, W. (2019), Conceptual design and performance evaluation of two-stage ultra-low binder ultra-high performance concrete. Cement and Concrete Research.125. https://doi.org/10.1016/j.cemconres.2019.
Mehta, A., Ashish, D. K. (2020), Silica fume and waste glass in cement concrete production: A review. Journal of Building Engineering. https://doi.org/10.1016/j.jobe.2019.100888
Mosavinejad, S. H. G., Langaroudi, M. A. M., Barandoust, J., Ghanizadeh, A. (2020), Electrical and microstructural analysis of UHPC containing short PVA fibers. Construction and Building Materials. 235. https://doi.org/10.1016/j.conbuildmat.2019.117448
Nordtest Method (1999). NT BUILD 492: Concrete, mortar and cement-based repair materials: chloride migration coefficient from non-steady-state migration experiments
Santos, L. (2006), “Avaliação da resistividade elétrica do concreto como parâmetro para a previsão da iniciação da corrosão induzida por cloretos em estruturas de concreto”. Dissertação de Mestrado, Universidade de Brasília, p.178
Sohail, M. G., Kahraman, R., Nuaimi, N.A., Gencturk, B., Alnahhal, W. (2021), Durability characteristics of high and ultra-high performance concretes. Journal of Building Engineering. 33. https://doi.org/10.1016/j.jobe.2020.101669
Sohail, M. G., Wang, B., Jain, A., Kahraman, R. (2018), Advancements in concrete mix designs: high-performance and ultrahigh-performance concretes from 1970 to 2016. Journal of Materials in Civil Engineering.30(3). http://dx.doi.org/10.1061/(ASCE)MT.1943-5533.0002144
Tam, C. M., Tam, V. W. Y., Ng, K. M. (2012), Assessing drying shrinkage and water permeability of reactive powder concrete produced in Hong Kong. Construction and Building Materials. 26:79-89. https://doi.org/10.1016/j.conbuildmat.2011.05.006
Teng, S, Afroughsabet, V., Ostertag, C. P. (2018). Flexural behavior and durability properties of high-performance hybrid-fiber-reinforced concrete. Construction and Building Materials. 182:504-515. https://doi.org/10.1016/j.conmat.2018.06.158
Yang, R., Yu, R., Shui, Z., Gao, X., Xiao, X., Zhang, Z., Wang, Y., He, Y. (2019), Low carbon design of an Ultra-High Performance Concrete (UHPC) incorporating phosphorous slag. Journal of Cleaner Production. 240. https://doi.org/10.1016/j.jclepro.2019.118157
Notas
Notas de autor

fgiannotti@ufscar.br


Figure 1
Recycled glass powder processing.
Source: Adapted from Freitas (2019).
Table1
Portland Cement physical characteristics.

Table 2
Silica fume and glass powder physical characteristics.

* tested according NBR 5751 (ABNT, 2015) method.** Reference values from NBR 12653 (ABNT, 2015).
Table 3
Fine aggregate physical characteristics.

Table 4
Materials chemical composition.

* Reference values from NBR 16697 (ABNT, 2018).** Reference values from NBR 13956-1 (ABNT, 2012).

Figure 2
Figure 2.

Figure 3
Slump flow test for consistency determination.
Table 5
Mixture ratios and consistency index for each composite.

Table 6.
Cementitious composites material consumption in kg/m³.

* Water consumption adjusted considering the solids content present in superplasticizer.

Figure 4.
Chloride diffusion test apparatus.
Table 7
Mechanical and physical characteristics of the UHPCC studied.


Figure 5
Effect of water-to-binder ratio on compressive strength of HPC and UHPC
Adapted from Sohail et al. (2018).
Table 8
Chloride penetration depth and chloride diffusion coefficient on 28-day age samples.


Figure 6
Chloride diffusion coefficient and penetration depth.
Tabela 9
Resistance to chloride penetration of various types of concrete based on the 28-day chloride diffusivity.

Adapted from Teng et al. (2018).